Products

B (bi-power) Series-High Frequency Design

HT-B-M1000-12

  Design feature

(1) Switch mode design.
(2) Compact and dexterous dimension design.
(3) Complete protection design---overload, overtemp, short circuit, high/low volt ...etc.
(4) Inverter re-start function.
(5) 3-stage charger design---bulk, absorption, float.
(6) Wide volt range operation (90~135V, 180~265V).
(7) Durable and corrosion resistant construction.
(8) Transformer isolated for safety.
(9) Bypass function.
  Wave form

Modified Sine Wave

  Socket type

  Multistage Charging Design

Model No.:
HT-B-M1000
INVERTER
DC input volt:
12V
Volt range:
10-16VDC
Surge power:
2000W
Continuous power:
1000W
Wave form:
Modified Sine Wave
AC voltage:
100V / 120V / 230V
Frequency:
50/60Hz ±3%
AC Regulation:
±8%(100V:±10%)
No load current draw:
0.6A
Bat. Low alarm:
10.5±0.5V
Bat. Low shutdown:
10±0.5V
Over voltage:
16±0.5V
Bat. Polarity Reverse:
Fuse burn out
Over load:
Re-start 1 time, shutdown if failed
Bypass function:
Yes
Low AC input volt transfer to inverter mode:
90Vac+/-5% or 180Vac+/-5%
Low AC input volt recovery to AC mode:
95Vac+/-5% or 190Vac+/-5%
Connector
Input AC Plug:
Yes
Output AC Receptacle:
Yes
CHARGER
Output current:
10A
AC input volt:
120V (90-135V) / 230V (180-265V)
Charging type:
multistage
Bulk stage:
14.5±0.5V,10A
Absorption stage:
14.5±0.5V, 10A-1A (12V)
Float stage:
13.6±0.5V, min, 0.5A (12V)
Frequency:
45-65Hz
Recommended Battery Type:
Lead acid
Recommended Battery Size:
40-160AH
PROTECTION
Over load protection:
Yes
Over temp protection:
Yes
Inverter input reverse protection:
Fuse blow
Charger output reverse protection:
Fuse blow
Inverter output short circuit protection:
Shut-off
Over temperture:
55℃±5℃
ENVIRONMENT
Working temp.:
-15℃~45℃
Storage temp.:
-25℃~70℃
Working humidity:
20%~90% RH non-condensing
Storage humidity:
-22℉~+158℉, 10~95% RH
Temp. Coefficient:
±0.05%℃ (0~55℃)
OTHERS
Dimension (LxWxH):
405x179x82.5 mm
Net weight:
4.0 kgs
※ Note: Specifications subject to change without notice.